日本熟妇一区二区三区,亚洲一区人妻在线,亚洲色在线九九久,女女亚成区视频,91久久精,日韩天堂久久在线,婷婷精品视频五区在线,五十路无码,久国产精品区

199-3021-7010

Transmitter Encyclopedia: Determine transmitter failure methods 1

Transmitter is commonly used in the industrial field of instrumentation, in the process of use, instrumentation failure is a more difficult problem in our work. Then, how to quickly and accurately determine the transmitter failure is very important. Star Instruments’ technicians have organized a set of transmitter failure judgment methods through years of work experience. Today, we first understand this method in the most simple and direct one – direct observation. This method is characterized by the need for other instruments, through the staff’s observation to find the source of the fault. Direct observation method to determine the transmitter fault method: First: check whether the transmitter shell and dial glass is intact, assembly fasteners are firm, whether the movable part of the rotation is flexible, adjust the part with or without obvious changes. Second: whether the connection line is disconnected, whether the connectors are normally connected, whether the reed on the circuit board socket is insufficient elasticity, poor contact, for the use of unit assembly instrumentation, pay special attention to the unit board connection screws are tightened. Third: each relay, contactor contacts, whether there are misplaced, stuck, oxidized, burnt and sticky phenomenon. Fourth: whether the transistor shell paint discoloration, broken poles, whether the resistor is burnt, whether the coil is broken wire, whether the capacitor shell is swollen, liquid leakage, burst and so on. Fifth: Observe whether the transmitter emits crackling sound, friction sound, banging sound. Sixth: Pay attention to whether there is a special odor inside the transmitter, such as the burnt insulation layer burnt and issued by the burnt flavor and so on. In the use of direct observation method for transmitter fault judgment is, need to pay attention to must be very careful and conscientious, do not be careless and impatient. In checking the components and wires can only be gently shaken, can not be too strong, in order to prevent broken components, wires. Power supply circuit in the large-capacity filter capacitors in the circuit with charging charge, to prevent electric shock. Do not leave the power switch when you turn on the power, if you find any abnormality, you should turn it off in time. Star Instruments Sensor Manufacturing Co., Ltd. is a high-tech enterprise integrating R&D, production and sales. Specializing in the production of pressure transmitters, level transmitters, temperature transmitters, temperature and humidity transmitters, differential pressure transmitters, soil moisture transmitters, 3051 transmitters and related instrumentation accessories. Many products under the brand of Star Instruments have obtained a number of patents issued by the state, such as CE certification, IS9001 certification, SGS certification, TüV SüD certification, explosion-proof certification and so on. For product consultation, product customization, agency, technical inquiries, quotations, etc., please contact Star Instruments: 400-600-4496 !
勃利县| 哈尔滨市| 永宁县| 舒兰市| 沧州市| 仙桃市| 剑川县| 宁海县| 古田县| 淮安市| 平潭县| 天长市| 盐城市| 慈溪市| 孙吴县| 新民市| 雅江县| 五原县| 托克逊县| 田东县| 榆社县| 宝兴县| 岳西县| 巧家县| 雅江县| 新疆| 青铜峡市| 含山县| 古丈县| 合水县| 宁晋县| 平泉县| 武乡县| 青田县| 砀山县| 贡山| 仁布县| 蓬莱市| 枣强县| 稻城县| 互助|