日本熟妇一区二区三区,亚洲一区人妻在线,亚洲色在线九九久,女女亚成区视频,91久久精,日韩天堂久久在线,婷婷精品视频五区在线,五十路无码,久国产精品区

199-3021-7010

Star Encyclopedia: Ten Precautions for Using Pressure Transmitters

Pressure transmitters are widely used for pressure measurement in liquid, gas, and process industries. Absolute pressure, negative pressure, and gauge pressure can be tested according to different models. A pressure transmitter is a precision instrument, and there are ten precautions that need to be noted and understood throughout the use of the pressure transmitter. Firstly, before installing the pressure transmitter, check for any interference around it. If there is a hidden danger of interference, it should be eliminated as much as possible or installed away from interfering equipment. Secondly, when wiring the pressure transmitter on site, thread the cable through the waterproof joint (accessory) or flexible pipe and tighten the sealing nut to prevent rainwater and other leakage into the transmitter housing through the cable. Thirdly, a voltage higher than 36V cannot be used on the pressure transmitter, as it may cause damage. Fourthly, when measuring gas pressure with a pressure transmitter, the pressure tap should be located at the top of the process pipeline, and the transmitter should also be installed on the top of the process pipeline to facilitate the accumulation of liquid into the process pipeline. Fifth, when measuring liquid pressure, the pressure tap should be opened on the side of the process pipeline to avoid sediment accumulation. Sixth, when measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the transmitter should not exceed the limit. And the buffer tube needs to be filled with an appropriate amount of water to prevent overheating steam from coming into contact with the transmitter. And the buffer heat dissipation pipe should not leak air. Seventh, when freezing occurs in winter, anti freezing measures must be taken for the transmitter installed outdoors to prevent the liquid in the pressure inlet from expanding due to freezing volume and causing damage to the sensor. Eighth, it is necessary to regularly clean the installation holes to ensure their cleanliness and prevent the pressure transmitter from coming into contact with corrosive or overheated media; Regularly clean the installation holes of the pressure transmitter to ensure their cleanliness. Ninth, the medium measured by the pressure transmitter should not freeze or freeze. Once frozen, it can easily damage the diaphragm, as the diaphragm is generally very thin. Tenth, the pressure pipe of the pressure transmitter should be installed in a place with small temperature fluctuations. If you have any questions regarding product consultation, product customization, agency, technical inquiries, quotations, etc., please contact Xingyi at 400-600-4496!
Click on the image to view the details>>
五大连池市| 塘沽区| 宣城市| 南漳县| 阿克苏市| 县级市| 鄂尔多斯市| 从化市| 西峡县| 万荣县| 墨脱县| 科技| 治县。| 昌江| 沂南县| 蓬莱市| 肃北| 太仆寺旗| 乌兰察布市| 灵宝市| 开封市| 吉木乃县| 客服| 博客| 北海市| 固镇县| 祥云县| 嵊泗县| 郑州市| 河池市| 长乐市| 泸州市| 合阳县| 托克逊县| 黄骅市| 双城市| 托里县| 鄢陵县| 太仆寺旗| 临颍县| 金塔县|